經(jīng)銷品牌
你的位置:首頁 » 產(chǎn)品中心 » Former(二手)儀器 » 網(wǎng)絡(luò)分析儀 » E5052B SSA Signal Source Analyzer--手機(jī)18912657535
儀器名稱: E5052B SSA Signal Source Analyzer--手機(jī)18912657535 儀器型號(hào): E5052B SSA Signal Source Analyzer 儀器品牌: Agilent 儀器指標(biāo): 10 MHz to 7 GHz, 26.5 GHz, or 110 GHz
Frequency range
- RF Input frequency range: 10 MHz to 110 GHz
- Analysis offset frequency range: 1 Hz to 100 MHz
- Phase noise measurement with ultra low noise floor and a cross-correlation method
- Frequency transient capture range: up to 80 MHz in narrow band, up to 4.8 GHz in wide band
Noise measurement functions
- Phase noise with ultra low noise floor and a cross-correlation method
- AM noise measurement and phase noise measurement without changing RF connection
- Baseband noise measurement from 1 Hz to 100 MHz
- Spectrum monitoring up to 15 MHz span in a real-time mode
Analysis capabilities
- Simultaneous transient measurements for frequency, phase and power over time
- Capture of unexpected frequency change with video trigger function
- Complete VCO characterization with outstanding low-noise DC sources(frequency/power/DC-supply-current over Vc and Vs)
- Clock jitter measurement with femto-second resolution
The E5052B 10 MHz to 7 GHz Signal Source Analyzer features a number of enhanced performance characteristics, partially shown in the key features above. And it offers world's highest measurement throughput and best usability in characterizing VCO or other types of high frequency signal sources, as well as clock jitter evaluation in high-speed data communication systems.
E5052B's frequency range can be extended up to 26.5 GHz with the E5053A, and up to 110 GHz with the E5053A plus Agilent 11970 series mixers.
The E5052B SSA is suitable for use in a wide range of applications including RF/uW/mmW oscillators, VCO's, system reference clocks, LAN modules, high-speed timing modules, SerDes chips, and high-speed data converters (ADC/DAC).
View:
- SSA-J Precision Clock Jitter Analysis with femto-second resolution
- Millimeter-wave phase noise test enables cross-correlation technique
Maintain your SSA: SSA Service & Support Home Page
E5052B-011 | Delete freq and power sweep function and limit correlation number and offset freq |
E5052B-1A7 | Calibration + Uncertainties + Guardbanding |
E5052B-1CM | Rackmount kit |
E5052B-1CN | Front handle kit |
E5052B-1CP | Handle/rack mount kit |
E5052B-810 | Add keyboard |
E5052B-820 | Add mouse |
E5052B-A6J | ANSI Z540-1-1994 Calibration |
1CN020A | Handle Kit 265.9mm H (6U) - Two Front Handles
Handle Kit 265.9mm H (6U) - Two Front Handles1CN020ATwo front handles |